Sprøjtefiltre

Sprøjtefiltre i forskellige udførelser til filtrering af væsker ved prøveforberedelse og analyse. Sortimentet omfatter filtre med forskellige porestørrelser, diametre og membranmaterialer afhængigt af anvendelse.

  • Sartorius

    Biohit Midi Plus, 1-100 ml

    Biohit Midi Plus er en let trådløs pipettedreng. Den passer til alle standard glas- eller plastpipetter og kan også bruges med Biohit 5 ml og 10 ml engangsspidser.  Hastigheden kan finjusteres ved at variere fingertrykket på betjeningsknapperne. Hydrofob autoklaverbart filter. Advarer om lavt batteriniveau. CE-mærket, 2 års garanti.
    710931 | LH-7129120
  • Sartorius

    Minisart GF+ SFCA 0.2µm Syringe Filter

    Minisart® NML Plus with glass fibre prefilter and surfactant-free cellulose acetate (SFCA) is optimized for particle-laden aqueous solutions or oils for a higher total throughput. Type 17823 with a pore size of 0.2 µm can be used for sterile filtration and has a male luer lock outlet.
    17823----------Q
  • Sartorius

    Minisart GF+1.2µm SFCA Syringe Filter

    Minisart® NML Plus with glass fibre prefilter and surfactant-free cellulose acetate (SFCA) is optimized for particle-laden aqueous solutions or oils for a higher total throughput. Type 17825 with a membrane pore size of 1.2 µm can be used for clarification and has a male luer lock outlet.
    17825----------Q
  • Sartorius

    Minisart NML 0.45µm, FM G-sterilized

    Minisart® NML Standard with surfactant-free cellulose acetate (SFCA) is the best choice for all aqueous solutions and oils with a pH of 4 - 8, sterilized by gamma irridation. It can be used for clarification and has a male luer lock outlet.
    S6555------FMGUK
  • Sartorius

    Minisart NML SFCA 0.45µm, Sterile

    Sterile Minisart®NML Standard with surfactant-free cellulose acetate (SFCA) is the best choice for all aqueous solutions and oils with a pH of 4 - 8. Type S7598 with a pore size of 0.45 µm can be used for for particle removal, clarification and bioburden reduction of aqueous liquids and has a male luer slip outlet. Sterilized by ethylene oxide (EO)
    S7598------FXOSK
  • Sartorius

    Minisart NY15 0.2µm Syringe Filter

    Minisart® NY with hydrophilic polyamide (nylon) is optimized for aqueous liquids and solvents with a pH of 3 - 14. Type 1776B with a pore size of 0.2 µm can be used for sample preparation and sterile filtration. It has a male luer slip outlet. Version K is a non-sterile pack. Units can be sterilized by autoclaving or EO.
    1776B----------Q | 1776B----------K
  • Sartorius

    Minisart NY25 0.45µm Syringe Filters

    Minisart® NY with hydrophilic polyamide (nylon) is optimized for aqueous liquids and solvents with a pH of 3 - 14. Type 17846 with a pore size of 0.45 µm can be used for sample preparation. It has a male luer slip outlet. Version Q is a non-sterile bulk pack. Units can be sterilized by autoclaving or EO.
    17846----------Q
  • Sartorius

    Minisart NY25 GF+0.45µm Syringe Filter

    Minisart® NY Plus with glass fibre prefilter and hydrophilic polyamide (nylon) is optimized for aqueous liquids and solvents with a pH of 3 - 14. Type 1784C with a pore size of 0.45 µm can be used for sample preparation. It has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    1784C----------K
  • Sartorius

    Minisart PES 0.2µm Sterile, Syringe Filter

    Minisart® High Flow with polyethersulfone (PES) is optimal for highest flow rates and a pH of 3 - 12. Type 16532 with a pore size of 0.22 µm can be used for sterile filtration and has a male luer lock outlet. Version GUK is sterilized by gamma irradiation, verison K with EO.
    16532----------K | 16532--------GUK
  • Sartorius

    Minisart PES 0.45µm Sterile, Syringe Filters

    Minisart® High Flow with polyethersulfone (PES) is optimal for highest flow rates and a pH of 3 - 12. Type 16537 with a pore size of 0.45 µm can be used for clarification and has a male luer lock outlet. Version K is individually packed and sterilized by ethylene oxide (EO).
    16537----------K
  • Sartorius

    Minisart PES 0.45µm, G-sterile, Syringe Filter

    Minisart® High Flow with polyethersulfone (PES) is optimal for highest flow rates and a pH of 3 - 12. Type 16533 with a pore size of 0.45 µm can be used for clarification and has a male luer slip outlet. Version GUK is individually packed and sterilized by gamma irradiation.
    16533--------GUK
  • Sartorius

    Minisart RC15 0.2µm Syringe Filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17761 with a pore size of 0.2 µm can be used for sample preparation and has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    17761----------Q
  • Sartorius

    Minisart RC25 0.2µm Sterile syringe filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17764ACK with a pore size of 0.2 µm can be used for sample preparation and sterile filtration. It has a male luer slip outlet and version ACK is individually packed and sterilized by ethylene oxide (EO).
    17764--------ACK
  • Sartorius

    Minisart RC25 0.45µm Syringe Filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17765 with a pore size of 0.45 µm can be used for sample preparation and has a male luer slip outlet. Version R is a non-sterile bulk pack. Units can be sterilized by autoclaving or EO.
    17765----------K
  • Sartorius

    Minisart SRP15 0.2 µm Sterile Syringe Filter

    Minisart® SRP with chemically inert hydrophobic PTFE is suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 17573 with a pore size of 0.2 µm can be used for sample preparation and sterile filtration. It has a male luer slip outlet and version ACK is individually packed and sterilized by ethylene oxide (EO).
    17573--------ACK
  • Sartorius

    Minisart SRP25 0.45µm Syringe Filter

    Suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 17576 pore size 0.45 µm can be used for sample preparation. It has a male luer slip outlet. Version K is a non-sterile pack. Units can be sterilized by autoclaving or EO.
    17576----------Q | 17576----------K
  • Sartorius

    Minisart SRP25 syringe filters

    Minisart® SRP with chemically inert hydrophobic PTFE is suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 17575 with a pore size of 0.2 µm can be used for sample preparation and sterile filtration. It has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    17575----------Q | 17575----------K
  • Sartorius

    MinisartCA_0,45µm_28mm_nsterile_500; (IVD)

    Provides fast and reliable filtration of small to medium volumes, complete with ready-to-connect filter units. Sartorius Minisart™ NML Syringe Filters, Nonsterile eliminate time consuming preparatory work, such as changing out the filter and cleaning the filtration system.
    17598----------Q
  • Sartorius

    MinisartGF_0,45µm_28 mm_sterile

    Minisart® NML Plus with glass fibre prefilter and surfactant-free cellulose acetate (SFCA) is optimized for particle-laden aqueous solutions or oils for a higher total throughput. Type 17829 with a pore size of 0.45 µm can be used for clarification and has a male luer lock outlet.
    17829----------K
  • Sartorius

    MinisartRC15 0.45µm Syringe Filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17762 with a pore size of 0.45 µm can be used for sample preparation and has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    17762----------K
  • Sartorius

    MinisartRC4 0.2µm Syringe Filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17821 with a pore size of 0.2 µm can be used for sample preparation and has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    17821----------K
  • Sartorius

    MinisartRC4 0.45µm Syringe Filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17822 with a pore size of 0.45 µm can be used for sample preparation and has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    17822----------K